Confocal microscope Olympus FV5000

NEW Confocal microscope Olympus FV5000


Transforming Precision Imaging Our more than 100 years of optical expertise have led to the FV5000 microscope—a technological breakthrough that delivers profound image quality with the potential to change what you’re able to see and empower your research.

Olympus Confocal FV5000


  • Superior image quality with our ultra-low-noise SilVIR™ detector and an industry-leading six channels, ten laser lines, and 400–900 nm dynamic range.


  • Unmatched dynamic range of 1 Gcps with high-SNR SilVIR detectors, trusted by leading research institutions


  • High-density pixel scanners with 8K fast galvo and 2K high-speed resonant imaging


  • FLUOVIEW Smart™ software interface and AI-powered workflows


  • TruResolution™ automated correction collar for instant spherical aberration correction with over 20 of our standard objectives


  • Modular, future-ready system design: Compact multiphoton upgrades




 

Biology in Motion, from Cells to Embryos


See biology in motion, in detail. From FRAP to ablation, SilVIR quantitative detection and fast scanning allow you to capture weak signals with minimal averaging, delivering high SNR at real-time frame rates.

In living samples, precise stimulation enables repeatable, targeted perturbations, so you can track repair, migration, and signaling over time. A wide linear dynamic range helps prevent saturation, keeping time-lapse data analysis-ready.


Time-lapse sequence in a living zebrafish embryo showing the repair response after localized multiphoton ablation of microtubules (green). Sample courtesy of: Soraya Villaseca, PhD , Department of Physiology, Development and Neuroscience, University of Cambridge.

End-to-End Simplicity with FLUOVIEW Smart™ Software


Inspired by real researchers tackling the challenges of science, the FV5000 is transforming confocal imaging, making it smarter and faster.


  • Smart Sample Searchquickly locates your sample in XY and Z


  • Smart Auto Laser Power Adjustmentuses AI to optimize signal-to-noise across power setting


  • Intuitive interfacecaptures complex multidimensional images in just a few clicks


  • Intelligent Shading Correctionautomatically creates seamless, high-quality stitched images


AI Imaging


Stunning, Data-Rich Images in Less Time and with Less Effort


Get better images in less time and with less effort.


TruAI™ denoise technology takes the already low-noise images from the FV5000 and reduces noise to ultra-low limits for stunning, data-rich resonant images.


To speed up image analysis, you can pre-train an AI model so that the system can automatically segment your image data, greatly reducing the workload of this often time-consuming manual process.

Then,TruAI technology further streamlines the analysis so that you can get your data quickly.


Image Segmentation Powered by Deep Learning


Go Beyond Conventional Thresholds

Traditional intensity-based thresholding can be slow, inconsistent, and highly sensitive to sample conditions.

TruAI image segmentation uses deep learning to recognize subtle patterns and faint signals that conventional methods miss, enabling accurate, reproducible segmentation of weakly labeled structures and complex tissues.

Clearly distinguish cells—and quickly find answers.

Near-Infrared Imaging Solutions


Near-Infrared Imaging Solutions
See in red—open a spectrum of possibilities. When investigating cellular
processes in the context of their 3D environments, model organisms and
organoids are often superior to 2D culture systems. Near-infrared (NIR)
microscopy has proven beneficial for imaging biological tissues due to a
lower absorption and scattering of NIR light than visible light.

Easy-to-Acquire, Quantitative Confocal Data


The FV5000 confocal microscope uses our advanced, silicon-based SilVIR™ detector that makes it easier than ever to acquire precise, reproducible data.


SilVIR Next-Generation Detector Technology

The SilVIR detector combines two advanced technologies—a silicon photomultiplier (SiPM) and our patented* fast signal processing design.


  • High dynamic range
  • Low noise
  • No degradation of sensitivity
  • Less sensitivity variation among other detectors

SilVIR Detector Technology


Silicon Photomultiplier


The detector’s silicon photomultiplier consists of multipixel Geiger-mode-operated avalanche photodiodes (APD). It can detect random incident photons simultaneously, enabling a higher photon detection efficiency for a wider range of wavelengths and dynamic range. It also provides quantitative data—the height of the output pulse precisely shows the number of detected photons.

Patented* Fast Signal Processing

See Deeper into Your Samples with Our New Multi-Immersion Objective


Our new multi-immersion objective (LUPLAPO25XS) with groundbreaking new immersion technology lets you see deeper into your samples and reveal structures that were previously out of reach.

New Experience with Silicone Gel Pad

LUPLAPO25XS
NA0.85 / WD 2.00mm*
Immersion: Silicone gel pad, Silicone oil, Water
* approx. 1mm for silicone gel pad

Gentler High-Speed Time-Lapse Confocal Imaging


Time-lapse imaging is easier with smart features:


  • Capture every moment of live cell dynamics: resonant scanner can acquire high-resolution images over a wide area
  • Minimal phototoxicity: the scanner’s short pixel dwell time reduces the time the focused laser beam rests on a single spot
  • Better signal-to-noise ratio: the SilVIR detector’s high sensitivity produces higher quality images at higher speeds
  • Greater precision: rolling average processing maintains qualifications and time resolution

HeLa cells labeled by MitoView 720. XYZT imaging by 1K resonant scanner for 30 min.

Flexible Macro to Micro Imaging


The macro-to-micro workflow enables you to easily observe the target sample from the macro level—whole body or tissue—down to the cell or subcellular level.

Overview and edge images of a Drosophila wing (42-hour pupation). Stained with phalloidin (AlexaFluor 405, F-actin, Cyan), anti-phosphotyrosine antibody (AlexaFluor 555, cell surface, red), and anti-HRP antibody (AlexaFluor 647, axon, blue).

Sample courtesy of: Sun Zhengkuan, Shigeo Hayashi, Laboratory for Morphogenetic Signaling, RIKEN Center for Biosystems Dynamics Research, Japan.

High-Quality Optics for Efficient NIR Fluorescence Imaging


The FV5000 system's optical elements have a high transmission from 400 nm to 1300 nm, including the galvanometer and resonant scanner, which are coated in silver rather than aluminum.


Our award-winningX Line™ objectivesare corrected for chromatic aberrations between 400–1000 nm. They also have a higher numerical aperture, excellent flatness, and very high transmittance from UV to NIR, increasing the multiplexing capabilities.


For improved colocalization reliability, ourspecialized A Line™ (PLAPON60XOSC2) oil immersion objective(ne~1.40) significantly minimizes chromatic aberration for strict colocalization analysis.

High-Resolution 3D Images in Thick Samples


When imaging thicker samples, the FV5000 microscope

enables you to capture high-resolution, 3D images.


  • Take advantage of NIR’s longer wavelength to penetrate deeper into tissue thanks to the SilVIR detector’s wide dynamic range and sensitivity
  • Image deeper with less scattering and absorption by taking advantage of the fact that light-scattering compounds—like melanin and heme—absorb less light between 700–1500 nm
  • Image significantly deeper than what’s possible with visible lasers thanks to 685 nm, 730 nm, and 785 diode lasers on the FV5000
  • High NA silicone objectives minimize spherical aberration and silicone oil doesn’t dry out, both advantageous for time-lapse imaging
  • Improve overall image quality and Z resolution using TruSight™ deconvolution for stunning 3D images of thick samples
  • Enjoy a seamless workflow from acquisition to publication with specialized cellSens™ software algorithms

HeLa cell spheroid labeled by DAPI (cyan, cell nuclei) and AlexaFluor790 (magenta, Ki-67). Imaging of the spheroid’s whole volume was possible by NIR 785 nm, although only surface area cell nuclei observation was possible using a 405 nm laser.

Time-lapse image of HeLa cells stained with Hoechst33342 (nuclear, blue), MitoTracker Green (mitochondria, green), LysoTracker Red (Lysosome, yellow), SiR-Tubulin (tubulin, magenta), POR-SA-Halo (ER, cyan). Hoechst33342: Ex 405 nm/Em, MitoTracker Green: LysoTrakcer Red: SiR-Tubulin: POR-SA-Halo: Sample courtesy of: Masayasu Taki, Ph.D., Institute of Transformative Bio-Molecules (WPI-ITbM), Nagoya University, Japan, Yuichi Asada and Ryusei Aruga, Graduate School of Science, Nagoya University, Japan.

Faster, Easier Image Analysis TruAI


Image analysis requires data extraction using segmentation techniques based on intensity value thresholds. However, this can be time-consuming and is affected by the sample conditions.

TruAI image segmentation using deep learning helps streamline image processing and minimize sample variables for more accurate image analysis. It enables you to segment superior performance with weak fluorescence fluorescence images or tissues that are usually difficult to extract using the simple thresholding method.

Configurations


The FV5000 microscope is engineered to be modular, making it easy for you to configure the system based on your applications and budget. You can start with a standard FV5000 and easily upgrade to multi photon imaging by adding the MPE module as your research changes.


One Platform for Your Research Needs


Multi photon and single-photon combination imaging in one sample is also possible. The FV5000MPE microscopes capable of second and third harmonic generation imaging, so different researchers or users can make the most out of the system. If your research requires a custom setup, the microscope’s modularity and optional ports enable you to customize the system to add extra lasers, cameras, detectors, and more.


FV5000MPE

Multiphoton Laser Scanning Microscope

Intuitive User-Interface and Workflows


The photomultiplier tubes traditionally used in confocal imaging require voltage adjustments depending on the sample’s brightness level as well as an offset adjustment to reduce signal noise. This requires expert knowledge and experience to make proper adjustments to acquire high-quality confocal images.


The SilVIR detector’s voltage is optimized for sensitivity and low noise at the factory, so you don’t need to make any voltage and offset adjustments—all you need to adjust is the laser power to achieve a certain photon number.

Since the signal-to-noise (S/N) ratio is proportional to the photon number, you can maintain consistent image quality by keeping the photon number constant.

Applications

Gustatory hair and Peudotrachea in Drosophila (42hours pupation)
Stained with Phalloidin (AlexaFluor 405, F-actin, Cyan), Anti-phosphotyrosine antibody (AlexaFluor 555, cell surface, red) anti-HRP antibody (AlexaFluor 647, axon, blue).
Sample Courtesy of: Sun Zhengkuan and Shigeo Hayashi, Laboratory for Morphogenetic Signaling, RIKEN Center for Biosystems Dynamics Research, Japan.

Neurofilament-heavy chain (NFH) in green, myelin basic protein (MBP) in red, glutathione S-transferase pi 1 (GSTpi) in blue. Mouse cerebellum captured with a UPLXAPO10X objective.
Sample courtesy of Katherine Given, Ph.D. Principal Investigator, Neurobiology University of Colorado Anschutz Medical Campus, Aurora, Colorado

Tip of a Drosophila leg (42-hour pupation), stained with phalloidin (AlexaFluor 405, F-actin, Cyan), anti-phosphotyrosine antibody (AlexaFluor 555, cell surface, red), and anti-HRP antibody (AlexaFluor 647, axon, blue).
Sample Courtesy of: Zhengkuan Sun, Shigeo Hayashi, Laboratory for Morphogenetic Signaling, RIKEN Center for Biosystems Dynamics Research, Japan.